Drugs & medical recalls in 2024
- 2024-12-31
CA
CA
CA
- 2024-12-30
CA
CA
CA
CA
CA
CA
CA
- 2024-12-27
CA
- 2024-12-25
US
Mint Medical GmbH recalls mint Lesion, Software Versions: 3.9.0 through 3.9.5.
Some software versions have a malfunction where they may show incorrect orientation labels for a specific subset of DICOM images.
FDA · DeviceMint Medical GmbHWorldwide distribution: US (nationwide): AR, CA, FL, GA, MI, MN, NY, OH, PA,…Official notice →US
Olympus Corporation of the Americas recalls Duravent Silicone Ventilation Tube. Model Number: 240075.
Potential that Duravent Silicone Ventilation Tubes may contain incorrect product, specifically, 1.32 mm Tiny T Tubes (model: 70240076) instead of the intended Duravent Silicone Ventilation Tubes.
FDA · DeviceOlympus Corporation of the AmericasAL, AZ, CA, IL, KY, MD, MN, MO, NC, ND, NY, OK, PA, SC, TN, TX, WA, WI.…Official notice →US
GE OEC Medical Systems, Inc recalls OEC 3D REF Image-Intensified Fluoroscopic X-Ray System, Mobile. The OEC 3D is a mobile fluoroscopic C-Arm imaging system used to…
Due to manufacturing issue of insufficient sealing of X-ray tubes and can result in a potential oil leak and loss of fluoroscopic imaging capability.
FDA · DeviceGE OEC Medical Systems, IncU.S.: AK, AZ, CA, CO, CT, DC, FL, GA, Guam, HI, IA, ID, IL, IN, KS, KY, LA,…Official notice →US
Augustine Temperature Management, LLC recalls Augustine Surgical Inc. HOT DOG PATIENT WARMING, Temperature Management Controller, Multiport, Models: 1) Model # WC77, 2)…
Instructions for use update on HotDog Temperature Management Controllers Models WC71, WC77, and Temperature Management Controller MP Model 2083516 pertaining to Power-on self-test error code "EA POST".
US
MicroPort Orthopedics Inc. recalls EVOLUTION MP FEMORAL COMPONENT CS/CR POROUS SIZE 5 RIGHT PRIMARY, REF: EFSRP5PR; EVOLUTION MP FEMORAL COMPONENT CS/CR NON-POROUS SIZE…
Femoral implant porous size 5 right primary and femoral implant non-porous size 6 left primary have correct markings on devices, but may have incorrect packaging.
US
MEDLINE INDUSTRIES, LP - Northfield recalls HUDSON RCI mBrace, ET Tube Holder with 4 Point Head Strap, REF DYNJMBRC4; tracheal tube fixation device
Complaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending…
US
Noah Medical recalls Galaxy System (GAL-001)
Bronchoscopic system uninterruptable power may have defective component, may cause power supply short circuit/trip protective circuit breakers causing sudden, unrecoverable power loss, which could occur while system is…
FDA · DeviceNoah MedicalUS: CA, MA, PA, NJ, ID, CT, MO, NC, MD, IL, TN, VA, OH, IN, WV, NYOfficial notice →US
CooperSurgical, Inc. recalls Brand Name: K-Systems Product Name: G85 Mini Incubator Model/Catalog Number: K22074 Software Version: N/A Product Description: An…
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
FDA · DeviceCooperSurgical, Inc.States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below,…Official notice →US
Philips North America Llc recalls Philips Smart-Hopping 2.0 AP 1.4 GHz. Model Number: 867216
The following four issues are included: 1. Certain Channel Settings may result in an Access Point preventing a connected client device from roaming to another Access Point potentially causing the client device to…
US
Spacelabs Healthcare, Ltd. recalls Eclipse PRO REF 98700 The Spacelabs model 98700 is a portable non-invasive Holter recorder intended to record the patient s ambulatory…
Due to a manufacturing error the incorrect device serial number was potentially programmed into the holter recorder. The physical serial number label on the device might not match the serial number programmed into the…
FDA · DeviceSpacelabs Healthcare, Ltd.U.S.: AR, CA, CO, DE, FL, FA, LA, MA, MI, MN, MT, NC, NE, NU OH, OR, PA,…Official notice →US
Spectranetics Corporation recalls Turbo Elite Laser Atherectomy Catheter Model Number / UDI-DI code / Product Description 414-151 / 989930000531 / 1.4 mm OTW 417-152 /…
Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.
FDA · DeviceSpectranetics CorporationU.S.: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, ILIN, KS, KY,…Official notice →US
Draeger Medical, Inc. recalls Brand Name: Atlan Product Name: Atlan A300XL Model/Catalog Number: 8621400 The Atlan is an anesthesia workstation intended for use in…
The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use or suffered a failure of the mechanical ventilation during use.
FDA · DeviceDraeger Medical, Inc.No Atlan A300 or A300XL devices were imported into the US. Devices were direct…Official notice →US
Medtronic Neurosurgery recalls Exacta External Drainage and Monitoring System: 27581 KIT 27581 EXACTA W/EDM VCATH 35CM 27636 EDM 27636 EXACTA W/BRAIDED CORD LOCK 27666…
Due to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS).
FDA · DeviceMedtronic NeurosurgeryWorldwide distribution. US nationwide including Puerto Rico; Algeria,…Official notice →US
Kirwan Surgical Products, LLC recalls Optikon Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: OPT14-5011. Product Description: The Disposable Microsurgical…
Potential for the outer stainless-steel tube to break or detach.
FDA · DeviceKirwan Surgical Products, LLCWorldwide - US Nationwide including PUERTO RICO; AUSTRALIA, CANADA, CHILE,…Official notice →US
Macleods Pharmaceuticals Ltd recalls Olanzapine Tablets, USP 2.5 mg, 30-count bottle, Rx Only, Manufactured for: Macleods Pharma USA, Inc. Princeton, NJ 08540,…
Failed Impurities/Degradation Specifications
US
US
Apothecus Pharmaceutical Corp. recalls VCF, Vaginal Contraceptive Gel, Birth Control, 10 Pre-filled Applicators, Net Wt. 0.09 oz (2.55g) Each, Distributed By: Apothecus…
CGMP deviations: out of specifications for assay
FDA · DrugApothecus Pharmaceutical Corp.Nationwide in the USA and 2 Distributors in Hong KongOfficial notice →US
US
Aurobindo Pharma USA Inc recalls Nebivolol Tablets, 2.5. mg, 30-count bottles, Rx only, Distributed by: Aurobindo Pharma USA, Inc., 279 Princeton-Hightstown Road, East…
CGMP Deviations: Presence of Nitrosamine Drug Substance Related Impurity (NDSRI), N-Nitroso Nebivolol above acceptable intake (AI) limit.
US
Keystone Industries recalls Gelato, Benzocaine 20% Topical Gel Anesthetic Gel, Net Wt. 1 oz. (30ml), Manufactured by Keystone Industries 480 S. Democrat Rd.,…
CGMP deviations: the bulk product was rejected by the Quality Unit after routine inspection of the mixing vessel showed scratches on the sides and bottom of the mixing vessel. Product was to be rejected but was…
FDA · DrugKeystone IndustriesNationwide in the USA and Canada, Dominican Republic, El Salvador, Honduras,…Official notice →- 2024-12-24
CA
CA
- 2024-12-23
CA
- 2024-12-20
CA
- 2024-12-19
CA
CA
Vitros® Chemistry Products System - DGXN Slides (Digoxin)
Labelling and packaging
Health CanadaOfficial notice →CA
CA
- 2024-12-18
US
Noah Medical recalls Galaxy bronchoscope (Product GALB-001) used with Instructions for use, Part: 10000752, part of the Noah Medical Galaxy System (GAL-001)
Not all biopsy tools meant to fit bronchoscope channel (2.1mm inner diameter/length greater or equal to 1100mm) will pass through if scope channel positioned in sharp bend (approx. greater than 100-deg.), excessive…
FDA · DeviceNoah MedicalUS Nationwide Distribution: SC, OH, PA, TN, MO, IN, CA, WV, NY, MD, MA, NJ,…Official notice →