GE Medical Systems, LLC recalls OEC Elite: The OEC Elite mobile C-arm is intended to provide fluoroscopic and digital spot images of the patient anatomy, interventional…
OEC Elite and OEC 3D Mobile C-Arms Exceeding 4% Source to Image Distance in X-ray Field.
Read the official notice →- Date
- 2025-06-18
- Country
- United States
- Brand
- GE Medical Systems
- Product
- OEC Elite: The OEC Elite mobile C-arm is intended to provide fluoroscopic and digital spot images of the patient anatomy, interventional…
- Classification
- Class II
- Units
- US and OUS
- Category
- Drugs & medical
- Source
- FDA · Device
Copied automatically from the US Food and Drug Administration. Details may be shortened or out of date; the official notice is the authoritative source. Disclaimer
What to do
- Check the product name, strength and lot number against the official notice.
- Do not stop a prescribed medicine without talking to your doctor or pharmacist first.
- Ask the pharmacy or supplier about a replacement or refund.
General guidance from Recall Atlas. The official notice from the US Food and Drug Administration has the exact models, batch codes and remedy, and it takes priority.
More GE Medical Systems recalls
- 2025-09-03
US
GE Medical Systems, LLC recalls GE HealthCare OEC 9900 Elite C-arm Systems.
GE HealthCare has become aware of a non-conformance to 21 CFR 1020.30 (k) in certain OEC 9800 and OEC 9900 Elite C-arm Systems. Specifically, impacted systems are missing the full layer of lead tape in the collimator…
- 2025-08-20
US
GE Medical Systems, LLC recalls GE Signa Artist, Nuclear Magnetic Resonance Imaging System
GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T,…
- 2025-07-30
US
GE Medical Systems, LLC recalls SIGNA Architect
GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result,…
FDA · DeviceGE Medical Systems, LLCWorldwide distribution - US Nationwide and the country of China.Official notice →- 2025-04-23
US
GE Medical Systems, LLC recalls Venue Go Models: R2 (Model Number H45181VG), R3 (Model Number H45193VG), R4 (Model Number H45114VG), R5 (Model Numbers H45135VG,…
The battery for certain ultrasound systems can potentially develop an internal failure which could result in smoke or fire.
- 2025-03-19
US
GE Medical Systems, LLC recalls GE Healthcare Revolution Apex, System, X-ray, Tomography, Computed
GE HealthCare has become aware of a potential issue on certain Revolution CT and Revolution Apex series CT systems (please see affected product details and the Appendix) that can result in coolant fluid (glycol)…
- 2025-02-12
US
GE Medical Systems, LLC recalls Optima XR646 HD. X-Ray imaging system.
The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still…
FDA · DeviceGE Medical Systems, LLCWorldwide Distribution: US (nationwide) including Puerto Rico and OUS…Official notice →
Other drugs & medical recalls in the United States
- 2025-06-18
US
Stryker GmbH recalls Long Nail, RIGHT Gamma4 10x320mm x 125, component of the Gamma4 System. Catalog Number: 84250320S.
Investigation confirmed that the GAMMA4 Right Long Nail was manufactured with the geometry of a left nail.
FDA · DeviceStryker GmbHWorldwide - US Nationwide distribution in the states of AL, FL, NJ, OR and the…Official notice →US
Fresenius Kabi USA, LLC recalls IVENIX INFUSION SYSTEM LVP Blood Products Administration Set, Dual-Inlet, Low-Sorbing, Y-Site, Mesh Filter, 15 mL. Intravascular…
Mis-assembly error of Blood Products Administrations Sets where the 200-micron drip chamber filter may be incorrectly positioned and unable to filter out large blood particulates.
FDA · DeviceFresenius Kabi USA, LLCUS distribution: CA, CO, DE, GA, IL, MD, MI, MN, MS, NC, NJ, NV, OK, SC, TX,…Official notice →US
Zyno Medical LLC recalls Z-800 Infusion System. Intended to provide intravenous infusion of parenteral fluids, blood, and blood products to a patient.
Unreleased software versions were installed on distributed devices without verification or validation.
US
Zydus Pharmaceuticals (USA) Inc recalls Icosapent Ethyl Capsules 1 gram, 120 Capsules per Bottle, Rx Only, Manufactured by Doppel Farmaceutici s.r.l., Piacenza, Italy,…
Failed Tablet/Capsule specifications; a product complaint was reported for burnt or melted capsules. This was determined to be a result of oxidation by leakage of capsule contents.
US
Amneal Pharmaceuticals, LLC recalls Sulfamethoxazole and Trimethoprim Tablets, USP, 400 mg/80 mg, Rx Only, a) 100 Tablets per Bottle, NDC: 65162-271-10, b) 500 Tablets…
Microbial contamination of non-sterile products: tablets may exhibit black spots due to microbial contamination.
US
Macleods Pharmaceuticals Ltd recalls Levothyroxine Sodium Tablets, USP 112 mcg (0.112mg), 1000 tablets, Rx Only, Manufactured for: Macleods Pharma USA, Inc. Princeton,…
Presence of a foreign substance: black hair found embedded in tablet.