MEDLINE INDUSTRIES, LP - Northfield recalls KIT,SPINE LH Convenience kit, SKU DYNJ906448A.
Surgical Patties & Surgical Strips in specific lots of Custom Convenience Kits were found to contain higher-than-expected levels of endotoxin within the raw material used to produce sterile Codman Surgical Patties and…
Read the official notice →- Date
- 2025-01-01
- Country
- United States
- Brand
- MEDLINE INDUSTRIES, LP - Northfield
- Product
- KIT,SPINE LH Convenience kit, SKU DYNJ906448A.
- Classification
- Class II
- Units
- US Nationwide. Canada.
- Category
- Drugs & medical
- Source
- FDA · Device
Copied automatically from the US Food and Drug Administration. Details may be shortened or out of date; the official notice is the authoritative source. Disclaimer
What to do
- Check the product name, strength and lot number against the official notice.
- Do not stop a prescribed medicine without talking to your doctor or pharmacist first.
- Ask the pharmacy or supplier about a replacement or refund.
General guidance from Recall Atlas. The official notice from the US Food and Drug Administration has the exact models, batch codes and remedy, and it takes priority.
More MEDLINE INDUSTRIES, LP - Northfield recalls
- 2025-01-22
US
MEDLINE INDUSTRIES, LP - Northfield recalls Medline Fluid Delivery Set with Drip Chamber: 1) MTO,135,YELLOW,MICRO,SPK-MAIMONIDES, Item Number: 60130527; 2)…
Fluid Delivery Sets were incorrectly assembled with a white macro drip chamber instead of the required grey micro drip chamber. The macro drip chamber delivers three times more fluid per drop than the micro drip chamber.
- 2025-01-08
US
MEDLINE INDUSTRIES, LP - Northfield recalls Medline custom medical procedure kits labeled as: 1) OPEN HEART CDS-LF, REFCDS840451M; 2) NEURO PACK, REFDYNJ41516M; 3) RFD-…
Custom convenience kits are being recall because the contain non-sterile Codman Surgical Patties & Surgical Strips, which have the potential for endotoxin contamination.
FDA · DeviceMEDLINE INDUSTRIES, LP - NorthfieldWorldwide distribution - US Nationwide and the countries of UAE, and Canada.Official notice →- 2025-01-01
US
MEDLINE INDUSTRIES, LP - Northfield recalls ST REPROCESSED BRUNS CURETTE #00 (BC00), Medline Item No. 67600K
Weak seals may result in a breach of sterility, which may not be detectable to the user. This can lead to increased risk of contamination and infection.
- 2024-12-25
US
MEDLINE INDUSTRIES, LP - Northfield recalls HUDSON RCI mBrace, ET Tube Holder with 4 Point Head Strap, REF DYNJMBRC4; tracheal tube fixation device
Complaint defects have been noted regarding the adhesive elements of the device and the frame of the holder putting additional pressure on the patient's cheekbones and upper lip which may cause dermal injury depending…
- 2024-12-11
US
MEDLINE INDUSTRIES, LP - Northfield recalls MEDLINE convenience kits labeled as: PORT INSERTION PACK, REF DYNJ81597
Medline is recalling medical convenience manufactured using certain lots of SafeAir Smoke Evacuation Pencil which were subsequently recalled by Stryker.
- 2024-12-04
US
MEDLINE INDUSTRIES, LP - Northfield recalls ENDO KIT, Medline Kit SKU DYKE1577A, Component Number 57469, 10 per case; Medline Convenience Kits containing Single Use…
Identified lots of Olympus product may be missing sterile and manufacturing lot numbers and expiration dates on the sterile packaging. The information can be found on the outer box or zipper bag label. Medline is…
FDA · DeviceMEDLINE INDUSTRIES, LP - NorthfieldUS Nationwide distribution in the state of NY.Official notice →
Other drugs & medical recalls in the United States
- 2025-01-01
US
Abbott Vascular Inc recalls 20/30 Priority Pack Accessory Kit w/Copilot, REF: 1003327, used for cardiovascular procedures.
Inflation Device used during cardiovascular procedures may leak in the indeflator at the hose rotating luer or at the gauge, which could lead to air embolism.
FDA · DeviceAbbott Vascular IncUS: IA, MD, DC, IN, CA, NV, TX, CT, GA, MS, NY, OH, FL, NC, MI, KY, PA, VA,…Official notice →US
O&M HALYARD, INC. recalls O&M Halyard Procedure Mask with SO SOFT* Earloops, Yellow-Disposable surgical mask Product Code: 47117
Not meeting the bioburden testing requirements of EN 14683 required for masks sold in Europe. Face masks sold in the United States are not required to meet this standard. However, if the standard is printed on the…
US
Beckman Coulter, Inc. recalls Access hsTnI Reagent, REF B52699, Immunoassay Method, Troponin Subunit. For the quantitative determination of cardiac troponin I (cTnI)…
Beckman Coulter, Inc. is recalling their Access hsTnI assay, a medical device by correction. The reason for the recall is: high troponin antigen (>55,000 pg/mL) can contaminate an analyzers probe and cause inter-assay…
US
Braemar Manufacturing, LLC recalls Monitoring Service Application (MSA). Software to process, analyze, display, and report cardiac events in ECG data received from…
Not all Electrocardiogram (ECG) events received July 2022-July 2024 were not properly routed and subsequently reviewed due to an analysis step being disabled with the monitoring service application software.
US
Hologic, Inc. recalls Panther Fusion SARS-CoV-2/Flu A/B/RSV Assay, REF: PRD-07400
SARS-CoV-2/Flu A/B/RSV Assay Kit may erroneously produce SARS-CoV-2 false positive results.
US
Nova Biomedical Corporation recalls StatStrip Glucose Ketone (mmol/L) Hospital Meter System. Model/Catalog Number: 63910. Prescription use blood glucose ketone meter for…
A software bug within the meter firmware leads to transmission of erroneous glucose and/or ketone patient test results to a healthcare institution's data management system (DMS) at healthcare sites using WiFi if a user…
FDA · DeviceNova Biomedical CorporationDistribution US Nationwide including Puerto Rico, Germany, Italy, Israel,…Official notice →