Mazor Robotics Ltd recalls Mazor X. Model Number REF TPL0059; stereotaxic orthopedic instrument
Software anomalies which can result in two separate issues: A lagging screen display during a navigated procedure; or the potential for a mismatch between the navigated screw and the screw information presented on the…
Read the official notice →- Date
- 2024-09-25
- Country
- United States
- Brand
- Mazor Robotics
- Product
- Mazor X. Model Number REF TPL0059; stereotaxic orthopedic instrument
- Classification
- Class II
- Units
- US Nationwide distribution in PR.
- Category
- Drugs & medical
- Source
- FDA · Device
Copied automatically from the US Food and Drug Administration. Details may be shortened or out of date; the official notice is the authoritative source. Disclaimer
What to do
- Check the product name, strength and lot number against the official notice.
- Do not stop a prescribed medicine without talking to your doctor or pharmacist first.
- Ask the pharmacy or supplier about a replacement or refund.
General guidance from Recall Atlas. The official notice from the US Food and Drug Administration has the exact models, batch codes and remedy, and it takes priority.
More Mazor Robotics recalls
- 2026-01-28
US
Mazor Robotics Ltd recalls Mazor X robotic guidance system REF: TPL0059
Software errors that can result in incorrect surgical instrument positioning during spinal surgery.
FDA · DeviceMazor Robotics LtdWorldwide distribution - US Nationwide and the countries of Australia,…Official notice →- 2023-10-18
US
Other drugs & medical recalls in the United States
- 2024-09-25
US
GE Healthcare recalls GE Healthcare Centricity Universal Viewer Zero Footprint Client, Model Numbers: a) 2110344-008; b) 2110344-009; c) 2110344-010; d)…
Footprint Client (ZFP) versions v6.0 SP9.x and SP10.x where the latest addended report is not shown by default to the user. The issue occurs when the addendum is created on the same day as the original report but at a…
US
ROi CPS LLC recalls regard Clinical Packaging Solutions, HT00376I - SPECIAL PROCEDURE, Item Number 800223009
Medical convenience kits were distributed with Merit syringes (manufactured by Jiangsu Shenli Medical Production) which were subsequently recalled.
US
MICROVENTION INC. recalls ERIC Retrieval Device REF: ER173020 ER174030 ER176044 The ERIC Retrieval Device is a mechanical thrombectomy device designed to restore…
Due to Retrieval Device product labels stating the incorrect expiration dates that (5 years instead of 3 years) which extends beyond their true expiration date.
FDA · DeviceMICROVENTION INC.U.S. Nationwide distribution in the states of AR, CA, FL, IN, LA, MA, MN, MO,…Official notice →US
Tornier, Inc recalls stryker TORNIER PERFORM HUMERAL SYSTEM - STEMLESS US Anatomic Nucleus, REF DWM003A; anatomic total arthroplasty of the shoulder
One lot of Perform Humeral Nucleus may exceed the specification for bacterial endotoxin load (max 20 EU/device).
FDA · DeviceTornier, IncUS Nationwide distribution in the states of IL, WI, AZ, NV, SD.Official notice →US
Cypress Medical Products LLC recalls General Purpose Syringe McKesson 60 mL Luer Lock Tip Without Safety, Catalog Number 869662, McKesson Brand Catalog Number: 102-S60C
The syringes that were inadvertently shipped from the Distribution Center. This product was on quarantine because FDA has stated that these syringes lack FDA clearance and were inadvertently shipped due to an internal…
FDA · DeviceCypress Medical Products LLCUS Nationwide distribution in the states of CA, NV, NY.Official notice →US
Medtronic Inc. recalls 2090 Programmers with serial number prefixes PKK0 and PKK1: a) 2090, Product Description: PRGM 2090 PROGRAMMER-PORTABLE CRM; b) 209031,…
Medtronic CareLink 2090 programmers with serial number prefixes PKK0 and PKK1 have the potential for autonomous cursor motion when Finger Touchscreen capability is enabled by software version 3.2 or higher.