Drugs & medicalClass II

Biocare Medical, LLC recalls intelliPATH Universal HRP Detection Kit, REF: IPK5011G80, containing DAB Buffer, Catalog Number: IPBF5009G20; ONCORE Pro DAB Chromogen,…

Kits containing the DAB chromogen buffer, intended for use in either manual or automated Immunohistochemistry (IHC) staining protocols, may produce weak to no staining, which may lead to test failure requiring the test…

Read the official notice →
Date
2024-11-13
Country
United States
Brand
Biocare Medical, LLC
Product
intelliPATH Universal HRP Detection Kit, REF: IPK5011G80, containing DAB Buffer, Catalog Number: IPBF5009G20; ONCORE Pro DAB Chromogen,…
Classification
Class II
Units
US Nationwide distribution in the states of MA, AZ, CT, NY, FL, NC, IN, IL,…
Category
Drugs & medical
Source
FDA · Device

Copied automatically from the US Food and Drug Administration. Details may be shortened or out of date; the official notice is the authoritative source. Disclaimer

What to do

  1. Check the product name, strength and lot number against the official notice.
  2. Do not stop a prescribed medicine without talking to your doctor or pharmacist first.
  3. Ask the pharmacy or supplier about a replacement or refund.

General guidance from Recall Atlas. The official notice from the US Food and Drug Administration has the exact models, batch codes and remedy, and it takes priority.

Other drugs & medical recalls in the United States

  1. 2024-11-13
  2. US
    Drugs & medicalClass II

    Ethicon, Inc. recalls Coated VICRYL Polyglactin 910 Suture VIO 36IN(90CM) USP0(M3.5) S/A CT, Product Number J358H

    Complaints were received regarding needle pull-off and suture degradation. Analysis on returned product from this lot confirmed that some sutures were visually degraded in the package.

    FDA · DeviceEthicon, Inc.International distribution to the country of China.Official notice →
  3. US
    Drugs & medicalClass II

    GE Healthcare recalls GE Healthcare Centricity Universal Viewer Zero Footprint, Model Numbers: 1) 2089507-083, GDZH-JINWAN-Centricity 2) 2089507-093,…

    GE HealthCare has become aware of an issue in Centricity Universal Viewer Zero Footprint Client (ZFP) where there is a potential security vulnerability which could allow a malicious actor to access the system and…

    FDA · DeviceGE HealthcareWorldwide distribution - United States Nationwide and the countries of…Official notice →
  4. US
    Drugs & medicalClass II

    SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION recalls SONIALVISION G4 is a multi-purpose X-ray R/F system. The equipment is suitable for radiographic and fluoroscopic…

    X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lead to the possibility of delay or…

    FDA · DeviceSHIMADZU CORPORATION MEDICAL SYSTEMS DIVISIONUS Nationwide distribution in the states of CA, CT, MA, WV, OH, NY, IA, NE,…Official notice →
  5. US
    Drugs & medicalClass II

    Nihon Kohden America Inc recalls Adult Cap-ONE Biteblock REF YG-227T The cap-ONE Biteblock is intended to sample CO2 and administer supplemental oxygen, for patients who…

    Due to products being shipped/distributed to customers after the products expiration date had past.

    FDA · DeviceNihon Kohden America IncU.S. Nationwide distribution in the states of CA, GA, ID, KY, MA, MO, NC, OR,…Official notice →
  6. US
    Drugs & medicalClass II

    Beckman Coulter, Inc. recalls The Access Cortisol assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of cortisol levels…

    The Access Cortisol assay protocol file (APF) applies an incorrect calibration curve acceptance parameter at the S1 calibrator level that can lead to a high rate of calibration failures which can vary by reagent lot…

    FDA · DeviceBeckman Coulter, Inc.Worldwide distribution.Official notice →
  7. US
    Drugs & medicalClass II

    Datascope Corp. recalls MEGA 7.5Fr. 40cc Intra-Aortic Balloon with Accessories, Model Number 0684-00- 0295-01

    There is discrepant labeling on the inner and outer packaging of the device.

    FDA · DeviceDatascope Corp.International distribution to the countries of Germany, Spain , Finland, Great…Official notice →
See all drugs & medical recalls →