B. Braun Medical, Inc. recalls Design Options COMBINED SPINAL/EPIDURAL TRAY- Intended for administration of analgesic/anesthetic agent to intrathecal space and epidural…
Incorrect catheter connector within the kit resulting in inability to provide a secure connection to the epidural catheter. The incorrect catheter connector is smaller than the required catheter connector and therefore…
Read the official notice →- Date
- 2025-02-05
- Country
- United States
- Brand
- B. Braun Medical
- Product
- Design Options COMBINED SPINAL/EPIDURAL TRAY- Intended for administration of analgesic/anesthetic agent to intrathecal space and epidural…
- Classification
- Class II
- Units
- US Nationwide distribution in the states of MO, OK.
- Category
- Drugs & medical
- Source
- FDA · Device
Copied automatically from the US Food and Drug Administration. Details may be shortened or out of date; the official notice is the authoritative source. Disclaimer
What to do
- Check the product name, strength and lot number against the official notice.
- Do not stop a prescribed medicine without talking to your doctor or pharmacist first.
- Ask the pharmacy or supplier about a replacement or refund.
General guidance from Recall Atlas. The official notice from the US Food and Drug Administration has the exact models, batch codes and remedy, and it takes priority.
More B. Braun Medical recalls
- 2025-07-02
US
B BRAUN MEDICAL INC recalls 0.9% Sodium Chloride Injection USP, 500 mL, packaged in 500 mL excel containers and further packaged 24 per case, Rx only, B.Braun Medical…
Lack of assurance of sterility: pinholes, within the finger boxes used during Form Fill Seal process resulting in leaks.
- 2025-04-16
US
B. Braun Medical Inc recalls 0.9% Sodium chloride Irrigation USP, Isotonic Solution for Irrigation, 500 mL Plastic Irrigation Container (PIC), B. Braun Medical, Inc.,…
Presence of Particulate Matter
FDA · DrugB. Braun Medical IncProduct was distributed to 12 distributors who may have further distributed…Official notice →- 2025-03-26
US
B Braun Medical Inc recalls Introcan Safety 3 Closed IV Catheter 22 Ga. x 1 in., PUR, Winged. Passive safety IV catheter.
Increased risk for valve housing detachment causing leakage.
FDA · DeviceB Braun Medical IncDomestic: CA, CA, FL, GA, IL, IL, IN, MD, MN, MO, NC, NM, NY, PA, TN, TX, VA,…Official notice →- 2024-09-25
US
B Braun Medical Inc recalls SL BLOODLINE FOR FMC 2008 SERIES-Tubing to be used to transfer blood between a patient and a haemodialyser during haemodialysis.…
Incomplete insertion of the patient connector of the Streamline Airless System Hemodialysis Bloodline to the Locksite may result in the potential for occlusion during prograde rinseback procedures. If the patient…
US
B. Braun Medical, Inc. recalls AET36 ANESTH EXT SET - Anesthesia Extension Set - Normally Closed Dual Manifold, Four-way Stopcock, Model/Catalog Number: 472036
Potential for product leakage from the Spin Lock Connector on the distal end of the device due to the migration of excess solvent during the assembly process.
- 2024-09-18
US
B Braun Medical Inc recalls Infusomat Space Infusion System/ Large Volume Pump, Product Code 8713050U
Extension of previous recall RES 92978. Pumps have the potential for upstream occlusion sensor to cease proper function due to buildup of electrostatic charge during operation triggering false downstream and upstream…
Other drugs & medical recalls in the United States
- 2025-02-05
US
Boston Scientific Corporation recalls AXIOS Stent and Delivery System 10mmx10mm UPN: M00553740
Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one.
FDA · DeviceBoston Scientific CorporationNationwide including Puerto Rico Foreign: To be providedOfficial notice →US
Accuray Incorporated recalls CyberKnife Treatment Delivery System, REF 0660000 The CyberKnife System may be labeled as CyberKnife M6TM or VSI TM Robotic Surgery…
Snap rings may become partially or completed detached from the shafts within the internal mechanism. Uncontrolled rotation may occur on the left and right roll axes when the rings are removed or damaged.
US
Medtronic Navigation, Inc. recalls Medtronic PIN, 100mm STERILE PERCUTANEOUS REF: 9733235 Medtronic PIN, 150MM, STERILE PERCUTANEOUS REF: 97733236 The Sterile…
Due to an increase in complaint that the percutaneous reference pin would not fit into the patient reference frame or percutaneous pin adapter.
FDA · DeviceMedtronic Navigation, Inc.Worldwide - U.S. Nationwide distribution including in the states of AK, AL,…Official notice →US
Instrumentation Laboratory recalls HemosIL Heparin Calibrators; Part Number: 0020300600; in vitro diagnostic
Control indicating lower than expected quality control (QC) results and in some instances QC recovery below the lower limit of the package insert acceptance range.
FDA · DeviceInstrumentation LaboratoryWorldwide - US Nationwide and the countries of Andorra, Algeria, Armenia,…Official notice →US
MEDLINE INDUSTRIES, LP - Northfield recalls Medline General Surgery Tray kits: 1) ARTERIAL LINE TRAY, Item Number ART600; 2) A LINE TRAY, Item Number ART690
The catheter subassembly in the Integrated Arterial Catheter was manufactured with excess material on the catheter hub.
US
SIEMENS MEDICAL SOLUTIONS USA, INC recalls ARTIS One Angiographic X-Ray System
A potential issue with ARTIS One systems was identified. In very rare situations, the first x-ray release following patient registration may be performed with incorrect copper prefiltration. If the described issue…