Recalls in 2022
By month
Most recalled brands
Tools & DIY recalls in the EU & EEA in 2022
- 2022-12-23
SI
EU
Particle filter mask (FAMEX FAGOMED) · Particle filtering half mask
The total filtration capacity of the mask is insufficient (measured mean values: as low as 67%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
FR
EU
Electric scooter (micro-mobility) · MICRO CONDOR II
The product's charging connector and metal frame have insufficient insulation. A user could touch these accessible live parts and receive an electric shock. The product does not comply with the requirements of the…
FI
EU
Wedge log splitter (Timco) · Fast log splitter
The area where log splitting takes place is not protected adequately. A user may introduce his hand or a finger in the area and have it cut by the blades, or have his palm crushed by the machinery. Furthermore, the…
DE
EU
Laser engraving machine (Atomstack) · Atomstack Lasergravierer A5 20 W
The product is not equipped with protective casing, while the protective cover always leaves an open gap between the laser head cover and the workpiece when used; in addition, the product may be operated without the…
- 2022-12-16
HU
EU
Chain saw attachment (DZT) · Electric chain saw Stand 12 PROFESSIONAL/ CHAIN SAW CONVERTER
The assembled chain saw is not equipped with a rear hand guard; the structure does not include a kickback protection device. In addition the machine with the conversion adapter (angle grinder) does not have a chain…
SI
EU
Particle filter mask (PROACTIVE-TEX) · Proactive-tex MASK- 05
The total filtration capacity of the mask is insufficient (measured values: as low as 85%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended…
SI
EU
Particle filter mask (IPOS) · Atemschutz-maske, Meltblown protective mask
The particle/filter retention of the material is insufficient (measured values: as low as 88%) and the total filtration capacity of the mask is insufficient (measured mean values: as low as 83%). Consequently, the…
SE
EU
Hair trimmer · Cordless split end hair trimmer
The solders in the product have an excessive concentration of lead (measured value up to 64% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Commission…
EU Safety Gate · reported by SwedenOfficial notice →- 2022-12-09
HU
EU
Laser pointer
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the requirements of the General Product Safety Directive nor with the European standard EN…
EU Safety Gate · reported by HungaryOfficial notice →CZ
EU
Particle filter mask (MOLAXISI) · PROTECTIVE MASK
The particle/filter retention of the material is insufficient (measured values: as low as 85%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
HU
EU
Particle filter mask (Jiedun) · KN95 Particulate Respirator
The total filtration capacity of the mask is insufficient (measured mean values: as low as 67%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
HU
EU
Laser pointer · "LASER POINTER"
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the requirements of the General Product Safety Directive nor with the European standard EN…
EU Safety Gate · reported by HungaryOfficial notice →- 2022-12-02
LU
EU
Particle filter mask · Shuter Life , KN95 Non-powered air-purifying particle respirator
The product advertises a protective potential against (viral) particles but its filtering capacity has not been tested by a relevant competent European conformity assessment body. Consequently, it is not proven that…
EU Safety Gate · reported by LuxembourgOfficial notice →HU
EU
Portable ozone generator (OZON Specialista) · HORDOZHATÓ ÓZONGENERÁTOR
The power cable of the device does not contain a protective contact and the accessible metal parts are not metallically connected to the protective earthing clamp screw. Live parts may become accessible and a user may…
ES
EU
LASER POINTER · LASER MONEY CHECK & LED LIGHT
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the requirements of the General Product Safety Directive nor with the European standard EN…
EU Safety Gate · reported by SpainOfficial notice →SI
EU
Angle grinder (LUX TOOLS) · LUX TOOLS E-WSS-21
The housing of the angle grinder does not have sufficient mechanical strength of the housing. If the grinding disc breaks, particles from the grinding disc will damage the angle grinder housing and give the user access…
HU
EU
Ozone generator (OZON Specialista) · Quartz csőrendszer
The active parts of the apparatus (high-voltage metal meshes) can be touched directly due to the lack of basic insulation and the possible release of the mains power cable. The user could touch accessible live parts,…
LU
EU
Robotic Lawn Mower · Robot Lifestyle
The product's lift and tilt sensors may not activate, and the mower may thus tilt and expose the blades or continue to operate, exposing any bystander to a risk of cuts. Furthermore, the mower can drive onto the foot…
EU Safety Gate · reported by LuxembourgOfficial notice →- 2022-11-25
LU
EU
Particle filter mask (DADDY'S CHOICE) · Protective Face Mask
The total inward leakage of the mask is too high, and the particle/filter retention of the material is insufficient (measured values: as low as 90%). Consequently, the product does not fulfil the health and safety…
DE
EU
Laser engraving machine (Twotrees) · Totem 60P
The product does not have a protective housing that prevents access to laser radiation, no manual reset nor key-operated main switch, and lacks an emission warning device. In addition, the laser does not switch off in…
DE
EU
Particle filter mask (Oley) · OLEY FFP2 NR
The total filtration capacity of the mask is insufficient (measured value: as low as 60%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended…
LU
EU
Hedge trimmer (Wolike)
The battery housing and the battery contact holder are not sufficiently resistant to ignition and can overheat. This can cause the user to suffer burns and can cause a fire. The product does not comply with the…
LU
EU
Hedge trimmer (East)
The battery housing and battery contact holder are not sufficiently resistant to ignition and can overheat. The user can therefore get burns and the product can cause a fire. The product does not comply with the…
- 2022-11-18
DE
EU
Laser engraving machine (LaserPecker) · LaserPecker L1
The product can be used without a protective casing/screen, and the protective cap on the laser head leaves a gap between the laser head cover and the workpiece when the laser head is at either its highest or lowest…
- 2022-11-04
FI
EU
Angle grinder (Brücke)
The main switch may become detached if the product receives a mechanical impact, leaving live parts exposed, causing an electric shock. The product does not comply with the requirements of the Machinery Directive, nor…
- 2022-10-28
DE
EU
Laser pointer · Laserpointer
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the requirements of the General Product Safety Directive nor with European standard EN…
EU Safety Gate · reported by GermanyOfficial notice →- 2022-10-21
PL
EU
Self-balancing scooter (hoverboard) (Kawasaki)
The product is not correctly insulated against water ingress. Water may enter the product which can damage the electric components causing it to overheat and catch fire. It may also cause a short circuit and make…
PL
EU
Scissor jack (STANMOT) · Podnosnik trapezowy
The product poses a risk of injuries because it is not sufficiently resistant to load. The product does not comply with the requirements of the Machinery Directive nor with the European standard EN 1494.
- 2022-10-07
HU
EU
Laser pointer (PUTEKCO) · LED TRAINING POINTER
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the European standard EN 60825.
FR
EU
Air compressor (Ningbo Huasheng Co. Ltd - SCHEPPACH) · Air compressor Ningbo Huasheng (HSNB) - SCHEPPACH
The product has a valve which does not correspond to the safety requirements. As a result, the valve can malfunction and cause excessive pressure on the tank, which could burst. Furthermore, the materials are too thin…
- 2022-09-30
SI
EU
Particle filter mask (Honeywell) · Filtering half mask
The total filtration capacity of the mask is insufficient (measured mean values: as low as 70%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
FR
EU
Air compressor (Quartz (Counterfeit)) · QUARTZ SIL540Q
The product has a valve which does not correspond to the safety requirements, the materials are too thin to withstand pressure, the pressure container supports (wheels, standing support) are not correctly welded and…
- 2022-09-23
CZ
EU
Particle filter mask (SHOUHUDUN) · Particle filter mask KN95 5 pack
The particle/filter retention of the material is insufficient (measured values: as low as 14%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
DE
EU
Laser marking machine
The screens of the machine do not reach the required protection level of 1. Due to the defective plate, reflected or diffused laser radiation can escape from the working area of the machine and cause damage to the…
EU Safety Gate · reported by GermanyOfficial notice →- 2022-09-16
HU
EU
Laser pointer (YHLASER) · GREEN LASER POINTER; Lézerfény
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The product does not comply with the relevant European standard EN 60825.
HU
EU
Laser pointer · GREEN LASER POINTER/Lézerfény
The laser beam is too powerful. Direct viewing of the laser beam could cause damage to sight. The insulation between the primary and accessible secondary circuits of the charger is not sufficient. The user could touch…
EU Safety Gate · reported by HungaryOfficial notice →DE
EU
Particle filter mask (MA Trading) · Disposable Protection Mask
The particle/filter retention of the material is insufficient (measured values: as low as 30%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
DE
EU
Particle filter mask (JU)
The particle/filter retention of the material is insufficient (measured values: as low as 80%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other…
- 2022-09-09
FR
EU
Agricultural tractor (CLAAS) · Arion 400
The parking brake may not engage or may disengage, due to a technical fault. This can lead to that the tractor cannot be immobilised, increasing the risk for an accident. The product does not comply with the Regulation…
- 2022-08-26
NO
EU
Particle filter mask (AIR QUEEN) · AIR QUEEN BREEZE FFP2 NR
The product bears a CE marking but its filtering capacity has not been tested by a relevant competent European conformity assessment body. Consequently, it is not proven that the product fulfils the health and safety…